Biennial and Annual Inspections of Fire Sprinkler Systems

FSI provides full routine re-inspections of existing fire sprinkler systems as required by the relevant standard and for the Building Warrant of Fitness. These requirements are to ensure each system is still compliant and any faults are identified. The relevant Standards for FSI fire sprinkler systems inspections are:

NZS 4541

Automatic fire sprinkler systems

Rules for the design, installation and maintenance of fire sprinkler systems so that systems reliably protect against the loss of life and minimize property damage from fire.

NZS 4515

Fire sprinkler systems for life safety in sleeping occupancies

Automatic fire sprinkler systems. (up to 2000 square metres) Applies to residential buildings such as hostels, boarding houses, apartment buildings, motels, retirement homes, transitional houses and hospital wards.

NZS 4517

Fire sprinkler systems for houses

Rules for the design, material, manufacture and installation of fire sprinkler systems for domestic occupancies.

Specialist Services

We offer a complete inspectorate service for your whole fire safety system. Our specialist services include inspections of new systems and alterations of existing Sprinkler Systems and more.

20201008_095020_resized
Testing of Isolating Valves and Flow Switches

Testing of Isolating Valves and Flow Switches

FSI provides annual testing for these elements. Flow switches indicate which part of the building has a fire so firefighters can quickly locate it. Isolating valves can be shut to enable repairs and maintenance of the fire sprinkler pipework. It is a requirement of NZS 4541 that these are testing routinely.

Read More

Hydrant Flow Testing

FSI has the staff and calibrated equipment to conduct multiple hydrant tests to confirm the performance of the hydrant main for use as a fire fighting water supply or as a source of water for a fire sprinkler system.

Read More
Backflow Prevention

Backflow Prevention

FSI provides backflow prevention testing annual as required, or in conjunction with the fire sprinkler inspection, to prevent water supply contamination where fire sprinkler systems are connected to portable supplies.

Read More

Inspection and testing of Special Hazard Systems

We inspect and test of Special Hazard Systems including Gas flood, deluge, water mist and tail end systems.

Read More
Supply of Inspection and Test Books

Supply of Inspection and Test Books

We also Supply of Inspection and Test Books Annual Fire Alarm Survey Book, Part 1 & 2 Bi-Annual Diesel Log Book Monthly Alarm Test Book Monthly Sprinkler Test Book

Read More

Inspection of New Sprinkler Systems

New fire sprinkler installations work in conjunction with your approved fire sprinkler contractor to inspect and test the new installation. This ensures compliance with the respective NZ Standard and the Building Consent.

Read More